CVLA Series Stainless Steel Vertical Multistage Water Pump
Delivery term:The date of payment from buyers deliver within days- Price:
Negotiable
- minimum:
- Total supply:
- Delivery term:
The date of payment from buyers deliver within days
- seat:
Shanghai
- Validity to:
Long-term effective
- Last update:
2024-02-15 13:05
- Browse the number:
251
- Shanghai Mislier Pump Industry Co., Ltd By certification [File Integrity]
-
Contact:
lanmsl(Mr.)
- Email:
- Telephone:
- Phone:
-
Area:
Shanghai
-
Address:
Room 402, Building 2, No.59, Jinma Road, Jiuting Town, Songjiang District, Shanghai
- Website: http://www.mislierpump.com/ http://lanmsl.shsanhui.com/
Product details
Pump
CVLA are non-self priming Vertical Multistage Water Pump, the pumps are
available with standard motor, the inlet and outlet
are located at the pump bottom at the same plane
(inline type).
All pumps are equipped with a maintenance-free
mechanical seal set of the cartridge type.
Â
Range | ||||||||||||||||
Rated Flow㎡n | 1 | 2 | 3 | 4 | 5 | 10 | 15 | 20 | 32 | 45 | 64 | 90 | 120 | 150 | 200 | 320 |
Temperature Range(℃) | -20 ~+104 | |||||||||||||||
Temperature On Range(℃) | -40 ~ +180 | |||||||||||||||
Max Efficiency(%) | 44 | 45 | 58 | 58 | 65 | 66 | 68 | 69 | 77 | 78 | 80 | 81 | 74 | 73 | 79 | 73 |
Flow Range(m³/h) | 0.7-2.4 | 1-3.2 | 1.2-4.5 | 2-4.8 | 2.5-8 | 5-13 | 9-24 | 10-29 | 14-40 | 20-56 | 30-85 | 40-120 | 60-150 | 80-180 | 100-240 | 160-360 |
Max Pressure (bar) | 22 | 25 | 24 | 25 | 24 | 22 | 23 | 25 | 28 | 26 | 20 | 20 | 16 | 16 | 16 | 16 |
High Pressure On Request(bar) | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 39 | 40 | 39 | 39 | Â | Â | Â | Â |
Motor power [KW] | 0.37-2.2 | 0.37-3 | 0.37-3 | 0.37-4 | 0.37-5.5 | 0.37-7.5 | 1.1-15 | 1.1-18.5 | 1.5-30 | 3-45 | 4-45 | 5.5-45 | 11-75 | 11-75 | 18.5-110 | 18.5-110 |
Material type | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â |
CVA Cast iron,S.S EN1.4301/AIS1 304 EN1.4401/AISI 316 | · | · | · | · | · | · | · | · | · | · | · | · | · | · | · | · |
CVFA,CVLA S.S EN1.4401/AISI 316 EN1.4401/AISI 3116 | . | . | . | . | · | · | · | · | · | · | · | · | · | · | · | · |
CVA pump pipe connection | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â |
Flange | DN25 DN32 | DN25 DN32 | DN25 DN32 | DN25 DN32 | DN25 DN32 | DN40 | DN50 | DN5O | DN65 | DN80 | DN100 | DN100 | DN150 | DN150 | DN150 | DN150 |
Flange on request | Â | - | - | - | - | DN50 | - | - | - | - | - | - | - | - | - | - |
CVFA/CVA/CVLA pump pipe connection | Â | Â | Â | Â | ||||||||||||
Colomn Pipe Thread * | G1 G1 ¼ | G1 G1 ¼ | G1 G1 ¼ | G1 G1 ¼ | G1 G1 ¼ | G2 | G2 ½ | G2 ½ | - | - | - | - | - | - | - | - |
Colomn Pipe Thread On Request * | G1 ½ | G1 ½ | G1 ½ | G1 ½ | G1 ½ | - | G2 | G2 | - | - | - | - | - | - | - | - |
Flange | DN25 DN32 | DN25 DN32 | DN25 DN32 | DN25 DN32 | DN25 DN32 | DN40 | DN50 | DN5O | DN65 | DN80 | DN100 | DN100 | DN150 | DN150 | DN150 | DN150 |
Flange On Request | - | - | - | - | - | DN50 | - | - | - | - | - | - | - | - | - | - |
Cutting ferrule joint[PJE]★ | G1 ¼ DN32 | G1 ¼ DN32 | G1 ¼ DN32 | G1 ¼ DN32 | G1 ¼ DN32 | G2 DN5O | G2 DN50 | G2 DN5O | - | - | - | - | - | - | - | - |
Â
Motor
Motor is totally enclosed, air-cooled two pole standard motor.
Protection grade: IP55
Insulation class: F
Motors of other voltages are available upon request.
Single phase motors are available from 0.37kw to 2.2kW
Standard voltage:
â— 50Hz: 1x220-230/240V
â— 3x200-220/346-380V
â— 3x220-240/380-415V
â— 3x380-415V
Â
Motor Protection
Single-phase motor have a built-in thermal overload switch.
Three-phase motors must be connected to a motor
protective circuit breaker according to local regulations.
Â
Ambient temperature
Ambient temperature: maximum+50℃ , if the ambient
temperature exceeds +50℃ , or the pump is installed
at an altitude exceeding 1000 meters, the motor must
not be fully loaded due to the risk of overheating.
Overheating may result from excessive ambient temperatures or the low density and consequently low
cooling effect of the air.
In such cases ,it may be necessary to use a motor with
a higher rated output.
Â
Terminal box positions
As standard the terminal box is mounted on the suction side of the pump,meanwhile, 0°,90°,180°,270°could be adjusted according to the following proceeding:
1.lf necessary, disassembling the protective cover of the shaft connector, but did not disassembling the
shaft connector.
2.Disassembling the motor fixation screws.
3.Turn the motor to the required direction.
4.Fasten the motor screws.
5.Install the shaft connector's protective cover.The voltage and frequency are marked on the label.the correct power should be confirm with the label before usage.
To ensure the electric connection is conformity to the drawing marked on the label inside the terminal box
Â
Viscosity
Â
This Vertical Multistage Water Pump of liquids with densities or kinematic viscosities higher than those of water will cause a consider-able pressure drop, a drop in the hydraulic performance and a rise in the power consumption.In such situations the pump should be fitted with a larger motor, if in doubt, contact Mislier.
Example
From the Fig.3, the pump is installed at an altitude exc-eeding altitude 3500 meters,P2 will decrease to 83% if the ambient temperature is up to 70℃,P2 will decrease to 78%.
http://www.mislierpump.com/
-
Luxury Fashion Garment Swing Tags and Jeans Clothing Hang Tags
price: Negotiable
-
8oz Single Wall Paper Cup
price: Negotiable
-
100 Polyester Knitted Fabric
price: Negotiable
-
Bottle Hang Tags Wine Bottle Liquor Bottle and Water Bottle Neck Gift Hang Tags
price: Negotiable
-
Electropolished Stainless Steel Tubing
price: Negotiable
-
Annealed Stainless Steel Tubing
price: Negotiable